PATENT DUCTUS ARTERIOSUS (PDA)

A PDA can cause left-to-right shunting associated with bronchopulmonary dysplasia, pulmonary hypertension, necrotizing enterocolitis, intraventricular hemorrhage, retinopathy of prematurity, and renal impairment.1

From week 6 of fetal life until birth, the ductus is responsible for most of the right ventricular outflow. Normally, functional closure of the ductus arteriosus occurs by about 15 hours of life in healthy, full-term infants.

 

INCIDENCE AND MORTALITY WITH PDA

  • In full-term infants, PDA accounts for 5%–10% of all congenital heart disease2
  • In preterm infants, the incidence of PDA can be up to 60%2
  • Among neonates with a birth weight ≤ 2.6 pounds (lb), 80% have PDA2
  • Among preterm infants presenting with respiratory distress syndrome, about 80% have PDA2
  • A PDA that fails to close by 2–3 days after birth may result in infant morbidity and mortality of up to 30%2
  • Left untreated, a PDA carries mortality rates of:3

BY AGE 20

BY AGE 45

BY AGE 60

Morbidities associated with PDA

Patients with a moderate left-to-right shunt may remain asymptomatic for years. However, historical series have shown that chronic volume overload may ultimately lead to severe complications:4

  • Congestive heart failure
  • Atrial arrhythmias
  • Irreversible hypertensive pulmonary vascular disease
  • Endarteritis
  • In rare cases: ductus aneurysm or acute aortic dissection

 

Congenital comorbidities associated with PDA

Atrial Septal Defect (ASD)5

Ventricular Septal Defect (ASD)5

Pulmonary Stenosis5

Mortality rates: why closure is essential

If PDA is left untreated, the mortality rate is 20% by age 20 years, 42% by age 45, and 60% by age 60.3

Complications from an untreated PDA may include heart failure, renal dysfunction, necrotizing enterocolitis, intraventricular hemorrhage, diminished nutrition and growth, and potentially chronic lung disease.

Patients with a large PDA, when untreated, are at risk of developing Eisenmenger Syndrome, in which the usual left-to-right shunting reverses to a right-to-left shunt. At this point the PDA is irreversible, PDA closure is contraindicated, and lung transplantation may be the only option for long-term survival.

Neonatal presentation at physical examination

Assessment can reveal:

  • Wide pulse pressure
  • Bounding peripheral pulses
  • Apnea (in neonates)
  • Unexplained metabolic acidosis
  • Hypotension and systemic hypoperfusion

Though not often observed in preterm infants, a murmur often obscures the second heart sound (S2). The murmur may be noticeable only during systole, or it may be a crescendo-decrescendo systolic murmur that extends into diastole.
 

Depending on the system affected by hypoperfusion, patients can also present with:

  • Respiratory failure
  • Cardiac hypertrophy
  • Renal dysfunction
  • Inability to tolerate feeding
  • Necrotizing enterocolitis

ABBOTT EVENTS

PremiClose is the only worldwide symposium focused on PDA closure in preterm infants. The goal of this event is to broaden PDA closure as a therapy in premature babies, and optimize the synergies between interventional pediatric cardiologists and neonatologists. Find out more about PremiClose's last edition in the section below.

FIND OUT MORE:

PDA Symposium 2024

Connext
TV

CONNECT TO THE LATEST
IN STRUCTURAL HEART
THERAPY

Find out more

References
  1. Sathanandam SK, Gutfinger D, O’Brien L et al. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams. Catheter Cardiovasc Interv. 2020;96(6):1266–1276. doi.org/10.1002/ccd.28973.
  2. Dice JE, Bhatia J. Patent ductus arteriosus: an overview. J Pediatr Pharmacol Ther. 2007;12(3):138–146. doi.org/10.5863/1551-6776-12.3.138.
  3. Kim LK. Patent ductus arteriosus (PDA). Medscape. emedicine.medscape.com/article/891096-overview. Accessed June 2023.
  4. Baruteau A-E, Hascoët S, Baruteau J et al. Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis. 2014;107(2):122–132. doi.org/10.1016/j.acvd.2014.01.008.
  5. Tripathi A, Black GB, Park Y-M M et al. Prevalence and management of patent ductus arteriosus in a pediatric Medicaid cohort. Clin Cardiol. 2013;36(9):502–506. doi.org/10.1002/clc.22150.
  6. Schneider DJ, Moore JW. Patent ductus arteriosus. Circulation. 2006;114(17):1873-1882. doi.org/10.1161/CIRCULATIONAHA.105.592063
  7. Philip R, Waller BR III, Agrawal V et al. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv. 2016;87(2): 310–317. doi.org/10.1002/ccd.26287.
  8. Gillam-Krakauer M, Reese J. Diagnosis and management of patent ductus arteriosus. NeoReviews 2018;19(7):e394–e402. doi.org/10.1542/neo.19-7-e394.
  9. Chaudhary N, Filipov P, Bhutada A et al. Controversies in the management of patent ductus arteriosus in preterm infants. J Neonatal Biol. 2016;5(4):1000238. doi.org/10.4172/2167-0897.1000238. www.walshmedicalmedia.com/open-access/controversies-in-the-management-of-patent-ductus-arteriosusin- preterminfants-2167-0897-1000238.pdf. Accessed June 2023.
  10. Nady ME, Amrousy DE, Salah N et al. Transcatheter versus surgical closure of patent ductus ateriosus in pediatric patients: A systematic review with meta-analysis. SM J Pediatr Surg. 2017;3(4):1054. www.jsmcentral.org/sm-pediatric-surgery/fulltext_smjps-v3-1054.pdf. Accessed June 2023.
  11. Zahn EM, Peck D, Phillips A et al. Transcatheter closure of patent ductus arteriosus in extremely premature newborns: Early results and midterm follow-up. JACC Cardiovasc Interv. 2016;9(23):2429–2437. doi.org/10.1016/j.jcin.2016.09.019.
  12. Van Overmeire B, Smets K, Lecoutere D et al. A comparison of ibuprofen and indomethacin for closure of patent ductus arteriosus. N Engl J Med. 2000;343(10):674–681. doi.org/10.1056/NEJM200009073431001.
  13. Stout KK, Daniels CJ, Aboulhosn JA et al. 2018 AHA/ACC Guideline for the Management of Adults with Congenital Heart Disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2019;139(14):e698–e800. doi.org/10.1161/ CIR.0000000000000603.
  14. Warnes CA, Williams RG, Bashore TM et al. ACC/AHA 2008 Guidelines for the management of adults with congenital heart disease. J Am Coll Cardiol. 2008;52(23):e143– e263. doi.org/10.1016/j.jacc.2008.10.001.
  15. Ashrafi AH, Levy VY. Management strategies for the preemie ductus. Curr Opin Cardiol. 2019;34(1):41–45. doi.org/10.1097/HCO.0000000000000580.
  16. Hamrick SE, Hansmann G. Patent ductus arteriosus of the preterm infant. Pediatrics. 2010;125(5):1020–1030. doi.org/10.1542/peds.2009-3506.
  17. Amplatzer Piccolo Occluder Instructions for Use.

© Abbott 2024. All rights reserved. 9-EH-5-14533-01 05-2024 REV A

You are about to leave my-connext.com

You are now leaving my-connext.com. Abbott is not responsible for any content published on the third-party website you are about to enter. Abbott has not reviewed and does not endorse any information presented on third-party websites.

The content on this website is intended for healthcare professionals in EMEA with applicable health authority product registrations, excepted those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011 article 34. Click OK to confirm you are a healthcare professional to proceed.

OK Decline