+
Site Tour
SURGICAL AORTIC
VALVE SOLUTIONS
TISSUE HEART VALVES (THV)

 

Our latest aortic valve replacement solution for optimizing key clinical outcomes and the possibilities for patient lifetime management.

  • PORCINE LEAFLETS
  • LOW AORTIC PROTRUSION
  • UNIQUE PERICARDIAL SHIELD
  • LARGE STENT INTERNAL DIAMETER
  • ADAPTIVE CUFF
  • PORCINE LEAFLETS natural internally mounted leaflet tissue with maximal opening (no muscle bar), complete leaflet coaptation (no central gap), no leaflet curtaining, and less calcification with reduced risk for stroke during reintervention.1

  • LOW AORTIC PROTRUSION mitigates the risk of coronary obstruction and sinus jailing


    FLEXFIT™ POLYMER STENT

    • Fractures at 8 atm2
    • Eases implant
    • Accommodates minimally invasive surgery
  • UNIQUE PERICARDIAL SHIELD provides a tissue-to-tissue interface to help prevent the risk of abrasion

  • LARGE STENT INTERNAL DIAMETER expands treatment options for patients by facilitating valve-in-valve* procedures with a wide range of Transcatheter Aortic Valve Implantation prostheses

  • ADAPTIVE CUFF
    Engineered to:

    • Allow maximum flexibility and easy passage through all anatomies
    • Prevent paravalvular leaks by sealing in all planes and minimizes parachuting resistance when delivering the valve onto the annulus valve-in-valve*

EPIC™ SUPRA AORTIC STENTED TISSUE VALVE FEATURES

Epic Max
1
2
3
4
5
  1. PORCINE LEAFLETS

    Natural internally mounted leaflet tissue with maximal opening (no muscle bar), complete leaflet coaptation (no central gap), no leaflet curtaining, and less calcification with reduced risk for stroke during reintervention.1

  2. LOW AORTIC PROTRUSION

    Mitigates the risk of coronary obstruction and sinus jailing

    FLEXFITTMPOLYMER STENT

    • Fractures at 8 atm2
    • Eases implant
    • Accommodates minimally invasive surgery
  3. UNIQUE PERICARDIAL SHIELD

    Provides a tissue-to-tissue interface to help prevent the risk of abrasion

  4. LARGE STENT INTERNAL DIAMETER

    Expands treatment options for patients by facilitating valve-in-valve* procedures with a wide range of Transcatheter Aortic Valve Implantation prostheses

  5. ADAPTIVE CUFF

    Engineered to:

    • Allow maximum flexibility and easy passage through all anatomies
    • Prevent paravalvular leaks by sealing in all planes and minimizes parachuting resistance when delivering the valve onto the annulus valve-in-valve*

RADIOPAQUE MAKERS AT ANNULUS AND STENT POSTS ENHANCES VISIBILITY FOR FUTURE VALVE-IN-VALVE*

*The safety and effectiveness of valve-in-valve procedures in an Epic™ Max valve has not been established

Connext
Live

REGISTER FOR OUR
VIRTUAL VENUE

Hear expert opinions first hand and collaborate on best practices.

Find out more

TV

References
  1. Keshishi, Melanie, et al. "Comparison of Modes of Failure and Clinical Outcomes Between Explanted Porcine and Bovine Pericardial Bioprosthetic Valves." Cardiovascular Pathology (2023): 107516.
  2. Allen, KB., Chhatriwalla, A., Cohen, DJ., et al.  Bioprosthetic valve fracture to facilitate transcatheter valve-in-valve implantation. Ann Thorac Surg. 2017;104:1501-1508.

© Abbott 2024. All rights reserved. 9-EH-5-14980-01 11-2024 REV A

You are about to leave my-connext.com

You are now leaving my-connext.com. Abbott is not responsible for any content published on the third-party website you are about to enter. Abbott has not reviewed and does not endorse any information presented on third-party websites.

The content on this website is intended for healthcare professionals in EMEA with applicable health authority product registrations, excepted those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011 article 34. Click OK to confirm you are a healthcare professional to proceed.

OK Decline