Designed for flexibility, our innovative duct occluder options conform to a variety of duct sizes while achieving complete patent ductus arteriosus (PDA) closure from a pulmonary or aortic approach.
SWITCH TO THE REFERRAL VIEW For more information specific to neonatology regarding PDA closure
AMPLATZER™ DUCT OCCLUDER:
FOR LARGE PDA CLOSURE
Backed by over 15 years of performance in the U.S.,1 the Amplatzer™ Duct Occluder can accommodate large PDAs with a single device—which can aid in minimizing the complexity of the procedure.
Features include:
- A conical shape that can help conform to tapering ducts
- A retention skirt to prevent embolization
Treatment range:
- Ductus diameter: 3.0–12.0 mm
- Ductus length: > 3.0 mm*
*The Amplatzer™ Duct Occluder can be used in any length defect as long as the device does not extend more than 3 mm into the pulmonary artery or does not occupy over half of the pulmonary artery lumen.
The Amplatzer™ Portfolio App helps physicians determine which Amplatzer Structural Interventions device to use by suggesting applicable devices based on respective Instructions for Use.
TV
- Data on file at Abbott.
- Philip R, Waller BR III, Agrawal V et al. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv. 2016;87(2): 310–317. doi.org/10.1002/ccd.26287.
- Schneider DJ, Moore JW. Patent ductus arteriosus. Circulation. 2006;114(17):1873-1882. doi.org/10.1161/CIRCULATIONAHA.105.592063.
- Amplatzer Piccolo™ Occluder Instructions for Use.
- Stout KK, Daniels CJ, Aboulhosn JA et al. 2018 AHA/ACC Guideline for the Management of Adults with Congenital Heart Disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2019;139(14):e698–e800. doi.org/10.1161/CIR.0000000000000603.
- Baruteau A-E, Hascoët S, Baruteau J et al. Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis. 2014;107(2):122–132.
doi.org/10.1016/j.acvd.2014.01.008. - Data on File, 302350-001_G Amplatzer™ Duct Occluder CER.
- Saliba Z, El-Rassi I, Abi-Warde MT et al. The Amplatzer Duct Occluder II: a new device for percutaneous ductus arteriosus closure. J Interven Cardiol. 2009;22(6):496–502.
doi.org/10.1111/j.1540-8183.2009.00504.x. - Gruenstein DH, et al. Transcatheter closure of patent ductus arteriosus using the Amplatzer™ Duct Occluder II (ADO II). Catheter Cardiovasc Interv. 2017;89(6):1118-1128. doi.org/10.1002/ccd.26968.